Advances in the diagnostics of eye diseases
DOI:
https://doi.org/10.15584/medrev.2016.4.10Keywords:
ophthalmology, diagnostics, optical coherence tomography, perimetryAbstract
The advances in the diagnostics of eye diseases have been presented in the work including the optic coherence tomography, confocal microscopy, ultrabiomicroscopy and perimetry.
Introduction: The advances in the diagnostics of eye diseases during the last decade of the 20th century and in 21st century is incomparable with the corresponding, earlier periods of development of that discipline. This can be attributed, inter alia, to the pace of the development of imaging techniquesat present at the level close to the histological picture.
Objective: The latest methods of diagnosis of changes of the front and back of the eye have been presented in the paper.
Material and method: The overview of the current national and foreign literature has been done, mainly for over 10 last years. The following databases have been searched: PubMed and Polska Bibliografia Lekarska.
Downloads
References
Niżankowska MH, Muzyka-Woźniak M, Oficjalska-Młyńczak J. Nowe trendy diagnostyczne i terapeutyczne w okulistyce. Przew Lek 2008;1:172-183.
Walczyk A, Fryczkowski A. Optyczna koherentna tomografia w diagnostyce i monitorowaniu chorób siatkówki. Stud Med 2011;22:45-49.
Hautz W, redaktor. OCT i angio-OCT w schorzeniach tylnego odcinka gałki ocznej. Warszawa: MediPage; 2015.
Fujimoto JG, Pitris C, Boppart SA et al. Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy. Neoplasia 2000;2:9–25.
Duchnik M, Machalińska A, Wiszniewska B. Prawidłowe i patologiczne obrazy badania optycznej koherentnej tomografii siatkówki - interpretacja w korelacji z obrazem histologicznym. Klin Oczna 2015;117:113-118.
Tarczyńska M, Kuźnik-Borkowska A, Kęcik D.Metody obrazowania zmian degeneracyjnych plamki. Okulistyka 2015; 18:14-19.
Al-Mujaini A, Wali UK, Azeem S. Optical Coherence Tomography: Clinical Applications in Medical Practice. Oman Med J 2013;28:86–91.
Rozegnał-Madej A, Bielecka E, Żarnowski T. Zastosowanie optycznej koherentnej tomografii w diagnozowaniu i monitorowaniu jaskry. Okulistyka 2013;16:58-62.
Teper S. Szerokokątna skaningowa oftalmoskopia laserowa w praktyce klinicznej. CX News 2015; 3:53.
Nowińska A, Wylęgała E, Teper S. Badanie przedniego odcinka oka. Obrazowanie przedniego odcinka oka przy użyciu optycznej koherentnej tomografii – wskazówki do interpretacji. W: Wylęgała E. Optyczna koherentna tomografia. Wrocław, Górnicki Wydawnictwo Medyczne; 2010.
Kałużny B, Sołdańska B. Topography and tomography of the cornea. Kontaktol Opt Okul 2012;1:5-9.
Tarnawska D, Wylęgała E, Nowińska A i wsp. Obrazowanie rogówki za pomocą optycznej koherentnej tomografii - analiza porównawcza czterech aparatów OCT. Okulistyka 2009;12:111-114.
Kałużny B, Piotrowiak I. Diagnostic techniques in keratoconus. Kontaktol Opt Okul 2010;3:5-9.
Kubiaczyk M. Współczesne metody diagnostyczne w dystrofiach rogówki. Przegl Okul 2011;5:4-5.
Tavakoli M, Hossain P, Malik RA. Clinical applications of corneal confocal microscopy. Clin Ophthalmol 2008;2:435–445.
Tesla P, Jędruch A, Sulak R. UBM w diagnostyce przedniego odcinka gałki ocznej. Okulistyka 2008;11:49-56.
Ishikawa H, Schuman JS. Anterior segment imaging: ultrasound biomicroscopy. Ophthalmol Clin North Am 2004;17:7–20.
Michalewska Z. Swept-source OCT (SS-OCT) czyli jak zajrzeć głębiej? TopCon News 2014;3;2-4.
Liu JL, Witkin AJ, Adhi M et al. Enhanced Vitreous Imaging in Healthy Eyes Using Swept Source Optical Coherence Tomography. PLoS One 2014; 9:7.
Gołębiewska J. AngioVue - nowa nieinwazyjna metoda oceny struktury siatkówki i funkcji mikrokrążenia. Okulistyka 2015;18:73-74.
Ang M, Sim DA, Keane PA et al. Optical Coherence Tomography Angiography for Anterior Segment Vasculature Imaging. Ophthalmology 2015;122:1740-7.
Bednarski M, Piasecka K, Michalewski J i wsp. SOCT w diagnostyce jaskry. Okulistyka 2011; 14:.33-36.
Przeździecka-Dołyk J. Współczesne możliwości badania pola widzenia. Przegl Okul 2013;6:6-7.
Yenice O, Temel A. Evaluation of two Humphrey perimetry programs: Full threshold and SITA standard testing strategy for learning effect. Eur J Ophthalmol 2005;15:209-212.
Artes PH, Henson DB, Harper R et al. Multisampling suprathreshold perimetry: a comparison with conventional suprathreshold and full-threshold strategies by computer simulation. Invest Ophthalmol Vis Sci 2003;44:2582-2587.
Tesla P. Perymetria automatyczna - nowe możliwości. Przegl Okul 2005;4: 2-9.
Schiefer U, Pascual P, Edmunds B. Comparison of the New Perimetric GATE Strategy with Conventional Full-Threshold and SITA Standard Strategies. Invest Ophthalmol Vis Sci 2009;50:488–494.
Gościniewicz P, Pieczara E, Romaniuk W. i wsp. Mikroperymetria w okulistyce. Mag Lek Okul 2011;5:189-193.
Acton JH, Greenstein VC. Fundus-driven perimetry (micro-perimetry) compared to conventional static automated perimetry: similarities, differences and clinical applications. Can J Ophthalmol 2013;48:358–363.
Romaniuk W, Gościniewicz P, Mrukwa-Kominek E. Kliniczne zastosowanie mikroperymetrii – wady i zalety tej metody. Doświadczenia własne. Post Nauk Med 2013;12:843-846.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2016 European Journal of Clinical and Experimental Medicine

This work is licensed under a Creative Commons Attribution 4.0 International License.
Our open access policy is in accordance with the Budapest Open Access Initiative (BOAI) definition: this means that articles have free availability on the public Internet, permitting any users to read, download, copy, distribute, print, search, or link to the full texts of these articles, crawl them for indexing, pass them as data to software, or use them for any other lawful purpose, without financial, legal, or technical barriers other than those inseparable from having access to the Internet itself.
All articles are published with free open access under the CC-BY Creative Commons attribution license (the current version is CC-BY, version 4.0). If you submit your paper for publication by the Eur J Clin Exp Med, you agree to have the CC-BY license applied to your work. Under this Open Access license, you, as the author, agree that anyone may download and read the paper for free. In addition, the article may be reused and quoted provided that the original published version is cited. This facilitates freedom in re-use and also ensures that Eur J Clin Exp Med content can be mined without barriers for the research needs.